[an error occurred while processing this directive]

NIST Time Scale Data Archive
Notes on NIST time scale, primary standards & services


  Return to Archive index   2002 2003 2004 2006 2007 2008 Current Year

Primary frequency standards developed and maintained by NIST are used to provide accuracy (rate) input to the BIPM. NIST-F1, a cesium fountain frequency standard, serves as the United States primary frequency standard. The uncertainty of NIST-F1 is less than 1 part in 1015.

The AT1 scale is run in real time using data from an ensemble of cesium standards and hydrogen masers. It is a free-running scale whose frequency is maintained as constant as possible by choosing the optimum weight for each clock that contributes to the computation.

UTC(NIST) is generated as an offset from our real-time scale AT1. It is steered in frequency towards UTC using data published by the BIPM in its Circular T. Changes in the steering frequency are usually made at 0000 UTC on the first day of any month, and the change in frequency in any month is limited to ±2 ns/day. The frequency of UTC(NIST) is kept as stable as possible at other times.

UTC is generated at the BIPM using a post-processed time-scale algorithm and is not available in real-time. The parameters that we use to generate UTC(NIST) in real-time are therefore based on an extrapolation of UTC from the most recent data available.

The table lists the parameters that are used to define UTC(NIST) with respect to our real-time scale AT1. To find the value of UTC(NIST) - AT1 at any time T (expressed as a Modified Julian Day, including a fraction if needed), the appropriate equation to use is the one for which the desired T is greater than or equal to the entry in the T0 column and less than the entry in the last column. The values of xls, x, and y for that month are then used in the equation below to find the desired value. The parameters x and y represent the offset in time and in frequency, respectively, between UTC(NIST) and AT1; the parameter xls is the number of leap seconds applied to both UTC(NIST) and UTC as specified by the IERS. Leap seconds are not applied to AT1.

   

UTC(NIST) - AT1 = xls + x + y(T - To)

Month xls(s) x (ns) y (ns/day) To (MJD) Valid
until 0000
UTC on:
MJD)
2005-12 -32 -286118.35 -39.1 53705 53736
2005-10 -32 -284308.25 -39.35 53659 53675
2005-10** -32 -283721.75 -39.1 53644 53659
2005-09 -32 -283017.95 -39.1 53626 53644
2005-09** -32 -282549.95 -39 53614 53626
2005-08 -32 -282081.95 -39 53602 53614
2005-08** -32 -281350.45 -38.5 53583 53602
2005-07 -32 -280156.95 -38.5 53552 53583
2005-06 -32 -279617.95 -38.5 53538 53552
2005-06** -32 -278993.95 -39.0 53522 53538
2005-05 -32 -277784.95 -39.0 53491 53522
2005-04 -32 -277160.95 -39.0 53475 53491
2005-04** -32 -276613.55 -39.1 53461 53475
2005-03 -32 -276066.15 -39.1 53447 53461
2005-03** -32 -275403.5 -39.0 53430 53447
2005-02 -32 -274311.15 -39.0 53402 53430
2005-01 -32 -273102.15 -39.0 53371 53402

* Provisional Value

** Rate Change in mid-month

Bibliography

Allan, D.W.; Hellwig, H.; and Glaze, D.J., " Requires Adove Acrobat Reader An accuracy algorithm for an atomic time scale," Metrologia, Vol.11, No.3, pp. 133-138 (1975).

Allan, D.W.; Davis, D.D.; Weiss, M.A.; Clements, A.; Guinot, B.; Granveaud, M.; Dorenwendt, K.; Fischer, B.; Hetzel, P.; Aoki, S.; Fujimoto, M.; Charron, L.; and Ashby, N., Requires Adove Acrobat Reader “Accuracy of International Time and Frequency Comparisons Via Global Positioning System Satellites in Common-view,” IEEE Transactions on Instrumentation and Measurement, Vol. IM-34, pp.118-125, 1985.

Jefferts, S.R.; Shirley, J.; Parker, T.E.; Heavner, T.P.; Meekhof, D.M.; Nelson, C., Levi, F.; Costanza, G.; De Marchi, A.; Drullinger, R.; Hollberg, L.; Lee, W.D.; and Walls, F.L., Requires Adove Acrobat Reader Accuracy evaluation of NIST-F1,” , Metrologia, Vol. 39, pp.321-336, (2002).

Lewandowski, W. and Thomas, C., "GPS time transfer," , Proceedings of the IEEE, Vol. 79, pp. 991-1000, (1991).

Shirley, J.H.; Lee, W.D.; Drullinger, R.E.; Requires Adove Acrobat Reader “Accuracy evaluation of the primary frequency standard NIST-7," Metrologia, Vol. 38, pp.427-458, (2001).

Weiss, M.A.; Allan, D.W.; Requires Adove Acrobat Reader “An NBS Calibration Procedure for Providing Time and Frequency at a Remote Site by Weighting and Smoothing of GPS Common View Data,” IEEE Transactions on Instrumentation and Measurement, Vol. IM-36, pp.572-578, (1987).

Home